OT/ICSCritical 9.4
CVE-2026-63353
Stored XSS in PLC trace import allows JS execution and unauthorized PLC actions.
How scary is it?
updated 28 Nov 2026- Yes
Works without logging in1
No account needed, but a person has to act, such as opening a link or a file (CVSS PR:N, UI:A).
- Yes
Reachable over the network1
Can be attacked remotely (CVSS AV:N).
- None known
Public exploit code is out
None on record in Exploit-DB, Metasploit, Nuclei templates or PoC-in-GitHub.
- None known
Attacks seen in the wild1
None reported that we know of. CISA's SSVC assessment says exploitation: none.
- No
On CISA's exploited list2
Not in the catalog as of our last sync.
Scare-o-meter
Routine patch
Serious on paper, with no sign of attacks that we know of. Patch in your normal cycle.
- Low signal
- Routine patch
- Act this week
- Drop everything
Why: our alert rule found no exploitation evidence and no easy remote attack path in the data we hold. Read from the same rule that decides our alert emails.
Are you affected? only if all are true
You run one of these 103 products in an affected versionSiemens SIMATIC Drive Controller CPU 1504D TF / Siemens SIMATIC Drive Controller CPU 1507D TF / Siemens SIMATIC ET 200SP CPU 1510SP-1 PN (+100 more)
Siemens SIMATIC Drive Controller CPU 1504D TF: < *
Siemens SIMATIC Drive Controller CPU 1507D TF: < *
Siemens SIMATIC ET 200SP CPU 1510SP-1 PN: < *
Siemens SIMATIC ET 200SP CPU 1510SP F-1 PN: < *
Siemens SIMATIC ET 200SP CPU 1512SP-1 PN: < *
Siemens SIMATIC ET 200SP CPU 1512SP F-1 PN: < *
Siemens SIMATIC ET 200SP CPU 1514SP-2 PN: < *
Siemens SIMATIC ET 200SP CPU 1514SP F-2 PN: < *
And 95 more in the table below.
As published in the CVE record. A version outside these ranges is not a statement that it is unaffected: vendors sometimes understate a range, and distribution builds with backported fixes keep the upstream number.
See the affected products table · Source 1
An attacker can reach it over the network
CVSS attack vector: Network (AV:N). Reachable over the internet or any routable network.
Source 1
A person takes an action, such as opening a link or a file
CVSS user interaction: required (UI:A). A victim must click, open or otherwise cooperate.
Source 1
Read from the CVE record: affected versions and the CVSS vector. It narrows things down. It does not prove you are safe.
What to do
Recommendation, AI-writtenBlock/unpublish trace import, remove 'Read diagnostics' rights from nonessential users, isolate PLC web UI, apply…
Block/unpublish trace import, remove 'Read diagnostics' rights from nonessential users, isolate PLC web UI, apply vendor patch when released
Written by a language model from the CVE record. It is not the vendor's wording: check it against the sources.
Steps marked AI were written by a language model, from the CVE record or from the linked news pages. They are not the vendor's wording: check them against the sources.
Major vulnerability. OT/ICS web UI vulnerability enabling remote manipulation of PLCs; impacts industrial control systems and could disrupt operations, making it high-profile for infrastructure owners.
- CVSS
- 9.4Criticalscored by the publisher (CNA)
- Exploited in the wild
- Not knownnot in CISA KEV as of our last sync
- EPSS
- 0.45%chance of exploitation in the next 30 daystop 69% of scored CVEsFIRST score of 28 Nov 2026
- Fix
- Not stated by the vendorno fixed release in the CVE record
- Published
- 13 Oct 2026analysed here 13 Oct 2026
Summary
Impact
Attacker can trick a user to import a crafted trace file, run attacker-controlled JS in the user's browser, and issue PLC commands within that user's authorization.
Triage
The summary, impact and action text on this page are written by our AI analysis pipeline, or taken from the NVD description when a CVE was imported from NVD. They are not the vendor's wording: check them against the sources. A longer AI executive summary and technical analysis are generated for signed-in accounts on the Max plan.
Affected products
| Product | Affected versions | Vendor says fixed in |
|---|---|---|
| Siemens SIMATIC Drive Controller CPU 1504D TF | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC Drive Controller CPU 1507D TF | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC ET 200SP CPU 1510SP-1 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC ET 200SP CPU 1510SP F-1 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC ET 200SP CPU 1512SP-1 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC ET 200SP CPU 1512SP F-1 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC ET 200SP CPU 1514SP-2 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC ET 200SP CPU 1514SP F-2 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC ET 200SP CPU 1514SPT-2 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC ET 200SP CPU 1514SPT F-2 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) V2 CPUs - Windows OS | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) V3 CPUs - Industrial OS | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) V3 CPUs - Windows OS | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC3 V4 CPUs | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1511-1 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1511C-1 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1511F-1 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1511T-1 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1511TF-1 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1512C-1 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1513-1 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1513F-1 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1513pro-2 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1513pro F-2 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1515-2 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1515F-2 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1515T-2 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1515TF-2 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1516-3 PN/DP | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1516F-3 PN/DP | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1516pro-2 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1516pro F-2 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1516T-3 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1516T-3 PN/DP | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1516TF-3 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1516TF-3 PN/DP | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1517-3 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1517-3 PN/DP | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1517F-3 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1517F-3 PN/DP | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1517T-3 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1517T-3 PN/DP | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1517TF-3 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1517TF-3 PN/DP | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1518-3 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1518F-3 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1518T-3 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1518T-4 PN/DP | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1518TF-3 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU 1518TF-4 PN/DP | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 Software Controller CPU 1507S F V2 | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 Software Controller CPU 1507S F V3 | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 Software Controller CPU 1507S F V4 | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 Software Controller CPU 1507S V2 | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 Software Controller CPU 1507S V3 | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 Software Controller CPU 1507S V4 | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 Software Controller CPU 1508S F V2 | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 Software Controller CPU 1508S F V3 | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 Software Controller CPU 1508S F V4 | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 Software Controller CPU 1508S TF V3 | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 Software Controller CPU 1508S T V3 | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 Software Controller CPU 1508S V2 | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 Software Controller CPU 1508S V3 | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 Software Controller CPU 1508S V4 | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 Software Controller Linux V2 | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-1500 Software Controller Linux V3 | < *Vendor says fixed in: not stated | |
| Siemens SIMATIC S7-PLCSIM Advanced | < *Vendor says fixed in: not stated | |
| Siemens SIPLUS ET 200SP CPU 1510SP-1 PN | < *Vendor says fixed in: not stated | |
| Siemens SIPLUS ET 200SP CPU 1510SP-1 PN RAIL | < *Vendor says fixed in: not stated | |
| Siemens SIPLUS ET 200SP CPU 1510SP F-1 PN | < *Vendor says fixed in: not stated | |
| Siemens SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL | < *Vendor says fixed in: not stated | |
| Siemens SIPLUS ET 200SP CPU 1512SP-1 PN | < *Vendor says fixed in: not stated | |
| Siemens SIPLUS ET 200SP CPU 1512SP-1 PN RAIL | < *Vendor says fixed in: not stated | |
| Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN | < *Vendor says fixed in: not stated | |
| Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL | < *Vendor says fixed in: not stated | |
| Siemens SIPLUS S7-1500 CPU 1511-1 PN | < *Vendor says fixed in: not stated | |
| Siemens SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL | < *Vendor says fixed in: not stated | |
| Siemens SIPLUS S7-1500 CPU 1511-1 PN TX RAIL | < *Vendor says fixed in: not stated | |
| Siemens SIPLUS S7-1500 CPU 1511F-1 PN | < *Vendor says fixed in: not stated | |
| Siemens SIPLUS S7-1500 CPU 1513-1 PN | < *Vendor says fixed in: not stated | |
| Siemens SIPLUS S7-1500 CPU 1513F-1 PN | < *Vendor says fixed in: not stated | |
| Siemens SIPLUS S7-1500 CPU 1515F-2 PN | < *Vendor says fixed in: not stated | |
| Siemens SIPLUS S7-1500 CPU 1515F-2 PN RAIL | < *Vendor says fixed in: not stated | |
| Siemens SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL | < *Vendor says fixed in: not stated | |
| Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP | < *Vendor says fixed in: not stated | |
| Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL | < *Vendor says fixed in: not stated | |
| Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL | < *Vendor says fixed in: not stated | |
| Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP | < *Vendor says fixed in: not stated | |
| Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL | < *Vendor says fixed in: not stated | |
| Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP | < *Vendor says fixed in: not stated | |
| Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP MFP | < *Vendor says fixed in: not stated | |
| Siemens SIPLUS S7-1500 CPU 1518F-4 PN/DP | < *Vendor says fixed in: not stated |
As published in the CVE Program record. A version outside these ranges is not a statement that it is unaffected — vendors sometimes understate a range, and distribution-backported builds carry upstream numbers that do not reflect what was patched into them.
Products named in our analysis
- Siemens devices with web-based Trace page
- Devices accepting trace file imports
- Accounts with 'Read diagnostics' privilege
Fix and mitigation
Action required
Immediate action required
WAF and other mitigations
Can a WAF block it? Yes. Cross-site scripting sends script tags or event handlers in the request, which WAF signatures match well.
Also consider: CSP · output encoding
Based on the weakness type only; no CVE-specific evidence yet. We check Cloudflare, AWS, Google Cloud Armor, Azure, F5 Distributed Cloud, Fastly, Imperva and Tencent EdgeOne. For Akamai we can read customer advisories but not the WAF rules: ask your vendor.
Remediation steps (AI-written)
Step-by-step remediation is generated for accounts on the Max plan, for CVEs that match a technology in their stack. Add this technology to your stack to see the fix checklist.
Exploitation evidence
- CISA KEV catalog
- Not listed as of our last sync.
- Public exploit code
- None on record in Exploit-DB, Metasploit, Nuclei templates or PoC-in-GitHub.
- CISA SSVC
- exploitation none, automatable no, technical impact totalAssessed by CISA 14 Oct 2026 (SSVC 2.0.3). Exploitation is none, poc (public proof of concept) or active.
Timeline
- 13 Oct 2026Published
- 13 Oct 2026Analysed by vulneraibility.comsame day later
- 14 Oct 2026CISA SSVC assessment: exploitation none1 day later
- 14 Oct 2026CVE record last updatedsame day later
Common questions
Is CVE-2026-63353 being exploited?
Not confirmed. CVE-2026-63353 does not appear in CISA's Known Exploited Vulnerabilities catalog, which records only exploitation that has been observed and reported publicly. That is evidence of absence of a report, not evidence the flaw is unattacked. EPSS currently estimates a 0.45% probability of exploitation in the next 30 days.
How severe is CVE-2026-63353?
CVE-2026-63353 is rated Critical with a CVSS score of 9.4. Severity describes how bad exploitation would be, not how likely it is: pair it with exploitation evidence before deciding what to patch first.
Is there a patch for CVE-2026-63353?
Not known from our data. No patch reference has been recorded for CVE-2026-63353, which is not the same as no patch existing — a fix may have shipped without a tagged reference, or after this record was written. The vendor advisory is the only authority on whether a fix exists, and mitigations may be available regardless.
What does CVE-2026-63353 affect?
CVE-2026-63353 affects Siemens devices with web-based Trace page, Devices accepting trace file imports, Accounts with 'Read diagnostics' privilege. Confirm the exact affected versions against the vendor advisory before deciding you are exposed.
What should I do about CVE-2026-63353?
Block/unpublish trace import, remove 'Read diagnostics' rights from nonessential users, isolate PLC web UI, apply vendor patch when released
Exploitation status reflects CISA's KEV catalog as we last synced it. Check the catalog directly.
References
NVDCVE.orgEUVD (ENISA)CVE DetailsSource
1 reference in the CVE record, grouped by the tags the record gives them.
Other links (1)
- cert-portal.siemens.com /productcert/html/ssa-591731.html
EU Vulnerability Database: EUVD-2026-98384
Where the data on this page comes from
- CVE List (CVE.org): description, affected versions, references; CVE Terms of Use
- NVD: CVSS and CPE data
- CISA Vulnrichment (ADP): SSVC decision points
- FIRST EPSS: exploit probability and percentile
- ENISA EUVD: EU vulnerability database id
Summary, impact and triage tags: written by our AI analysis pipeline from the sources above. Check them against the sources.
Similar CVEs
Ask your AI assistant about this CVE
Our MCP server answers questions about the CVEs we have analysed. It needs no account and no key: add this address as an MCP server in Claude, ChatGPT, Cursor or another client.
MCP server address: https://www.vulneraibility.com/api/mcp
In Claude or ChatGPT: Settings, then Connectors, then Add custom connector. Name vulneraibility, the address above, no authentication. Steps for each client
Then ask, for example:
Use the vulneraibility tools to read CVE-2026-63353. Is it being exploited, which versions are affected, and what fixes it?
Without a key it can search and read CVEs. To check your own stack, or to have your assistant apply a fix that we then verify, it needs an API key (Max plan). How to connect
Get CVEs like this by email. Join the free digest: the CVEs we flag as major, all CVSS 8.0 or higher, in up to three emails a day (sent at 05:00, 11:00 and 15:00 UTC). Matching alerts to the products you run needs an account, and accounts are invite-only during the beta.