Skip to content
major vulnerability· requires attention

RCE/DoS in widely deployed Siemens building/automation controllers; can disrupt facilities and operational infrastructure across organizations.

IoT

CVE-2021-31886

9.8
Critical
EPSS 3%Patch availableSep 2, 2026

FTP USER buffer overflow in Siemens building controllers allows remote code execution or DoS.

common questions

Is CVE-2021-31886 being exploited?

Not confirmed. CVE-2021-31886 does not appear in CISA's Known Exploited Vulnerabilities catalog, which records only exploitation that has been observed and reported publicly. That is evidence of absence of a report, not evidence the flaw is unattacked. EPSS currently estimates a 3.0% probability of exploitation in the next 30 days.

How severe is CVE-2021-31886?

CVE-2021-31886 is rated Critical with a CVSS score of 9.8. Severity describes how bad exploitation would be, not how likely it is: pair it with exploitation evidence before deciding what to patch first.

Is there a patch for CVE-2021-31886?

Yes. A fix has been recorded for CVE-2021-31886. The vendor advisory is the authority on the exact fixed version — apply it from there rather than from a summary.

What does CVE-2021-31886 affect?

CVE-2021-31886 affects Siemens APOGEE PXC (Compact/Modular), Siemens APOGEE MBC/MEC, Siemens Desigo PXC series, Siemens TALON TC (Compact/Modular), and 1 further product or version. Confirm the exact affected versions against the vendor advisory before deciding you are exposed.

What should I do about CVE-2021-31886?

Apply Siemens updates immediately; block/limit FTP, isolate controllers, monitor logs.

Exploitation status reflects CISA's KEV catalog as we last synced it. Check the catalog directly.

executive summary
technical analysis
affected
Siemens APOGEE PXC (Compact/Modular)Siemens APOGEE MBC/MECSiemens Desigo PXC seriesSiemens TALON TC (Compact/Modular)Siemens Nucleus NET/ReadyStart/Source Code
impact

Remote code execution or denial of service via crafted FTP USER command, enabling full control or outage of building controllers.

action required

Immediate action required

affected versions
Siemens APOGEE MBC (PPC) (BACnet)
  • affectedAll versions
Siemens APOGEE MBC (PPC) (P2 Ethernet)
  • affectedAll versions
Siemens APOGEE MEC (PPC) (BACnet)
  • affectedAll versions
Siemens APOGEE MEC (PPC) (P2 Ethernet)
  • affectedAll versions
Siemens Nucleus NET
  • affectedAll versions
Siemens Nucleus Source Code
  • affectedAll versions

As published in the CVE Program record. A version outside these ranges is not a statement that it is unaffected — vendors sometimes understate a range, and distribution-backported builds carry upstream numbers that do not reflect what was patched into them.

how to fix
Remediation steps are tailored for users whose stack is affected. Add this technology to your stack to see the fix checklist.
references
get alerted

Track only the vulnerabilities that affect your infrastructure.

start for free